Heating And Cooling Circulators
<p>The Refrigerated Heating Circulators is equipped with both cooling and heating modules, allowing for precise control over a wide temperature range with just one device, and supporting quick switching between cold and hot modes.</p><p>Suitable for scenarios that require high dynamic temperature control systems, such as alternating control of exothermic and endothermic reactions in chemical reaction vessels, high a…
About this product
Product information from the supplier.
The HAC heat recovery chiller offers precise temperature control. It is designed for heating and cooling in process applications. The system includes heating, cooling, circulation, and control functions. The heat transfer fluid moves between the reactor jacket and the chiller. This allows stable and efficient heat exchange. Users can set and monitor the temperature in real time.
Product features
Temperature range and precision
One of the key features of laboratory standard type heating and cooling circulators is their wide temperature range. These circulators can typically achieve temperatures ranging from -25°C to +200°C, allowing for precise control over a broad spectrum of applications. Moreover, they offer high temperature stability and control within a few degrees of the set temperature.
Pump capacity and circulation rate
Heating and cooling circulators are equipped with powerful pumps that ensure efficient circulation of the temperature-controlled fluid. The pump capacity and circulation rate vary among different models, enabling users to select circulators based on their specific needs. The faster the rate of circulation, the quicker the temperature equilibrium within the vessel.
Safety features and monitoring capabilities
Laboratory standard type heating and cooling circulators come with various safety features to safeguard laboratory processes and personnel. These features may include over-temperature protection, low liquid level detection, and alarms. Additionally, most circulators incorporate monitoring capabilities such as digital temperature displays and programmable controllers for precise control and monitoring.
Applications and Benefits
Heating and cooling circulators find applications in diverse fields within laboratory settings:
1. Research and development: In scientific research, laboratory standard type circulators are utilized to maintain controlled temperatures during experiments, ensuring reliable and reproducible results.
2. Pharmaceutical and chemical industries: The pharmaceutical and chemical industries rely on heating and cooling circulators for processes like drug development, chemical synthesis, and sample preparation. Precise temperature control facilitates the synthesis of complex chemical compounds.
3. Testing and quality control processes: Industrial laboratories employ heating and cooling circulators to test materials and products for various parameters, ensuring compliance with quality standards. These circulators aid in environmental testing, material characterization, and calibration processes.
Benefits of precise temperature control include:
- Improved experimental reproducibility
- Enhanced product quality and consistency
- Accelerated reaction rates and reduced process times
Choosing the Right Circulator
When selecting a laboratory standard type heating and cooling circulator, several factors need consideration:
Temperature range and stability requirements
- Assess the temperature range required for your specific application.
- Consider the required temperature stability and precision to meet experimental needs.
Pump capacity for circulation needs
- Analyze the volume and characteristics of the fluid being circulated.
- Ensure the circulator's pump capacity meets the circulation requirements.
Integration with laboratory equipment
- Evaluate compatibility with existing laboratory tools or instruments.
- Consider the availability of communication protocols for integration.
Energy efficiency and environmental considerations
- Opt for circulators with energy-saving features and environmentally friendly refrigerants.
- Efficient models contribute to cost reduction and lower environmental impact.
Installation and Setup
Before installation, the following steps should be considered:
Positioning and space requirements
- Plan the location and ensure sufficient space for the circulator, taking into account access for maintenance.
Electrical and plumbing connections
- Follow manufacturer guidelines for electrical and plumbing connections.
- Ensure proper grounding and adhere to safety standards.
Calibration and temperature settings
- Calibrate the circulator according to the manufacturer's instructions.
- Configure the desired temperature settings based on the experiment's requirements.
Maintenance and Troubleshooting
FAQS
1. What is the difference between a heating and cooling circulator and a water bath?
- Unlike a water bath that provides a fixed temperature, a heating and cooling circulator offers precise temperature control and stability over a wide range. It also facilitates faster temperature equilibration due to active circulation.
2. Can a heating and cooling circulator maintain a constant temperature for extended periods?
- Yes, laboratory standard type heating and cooling circulators are designed to provide consistent temperature control over extended periods of time. However, regular maintenance and calibration are essential to ensure optimal performance.
3. Are laboratory standard type heating and cooling circulators suitable for small-scale experiments?
- Absolutely! Heating and cooling circulators are available in various sizes, making them suitable for both small-scale and large-scale experiments. It's important to select a circulator with an appropriate pump capacity for the desired circulation needs.
4. Can the circulator be used with different types of fluids?
- Yes, laboratory standard type heating and cooling circulators can be used with various fluids, including water, oils, and other temperature-compatible liquids. Different circulator models may have specific recommendations for optimal fluid types.
5. What safety precautions should be followed when using a heating and cooling circulator?
- Always follow the manufacturer's instructions and safety guidelines provided with the circulator. This includes proper electrical grounding, regular maintenance, and regular checks for leaks or malfunctions. Avoid exposing the circulator to extreme environments or operating it near flammable materials.
Technical specifications
Model | HAC-35N | HAC-50N | HAC-70N | HAC-100N | HAC-150N | |
Temp rang | -25℃~200℃ | |||||
Temp accuracy | ±0.5℃ | |||||
Heating power KW | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
Cooling | 200℃ | 3.5kW | 5.5kW | 7kW | 10kW | 15kW |
100℃ | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
20℃ | 3.5kW | 5.5kW | 7kW | 10kW | 15kW | |
-5℃ | 3kW | 4.5kW | 6.6kW | 8kW | 12kW | |
-15℃ | 1.8kW | 2.8kW | 3.8kW | 4.6kW | 7kW | |
Circulation pump flow | Max35L/min | Max35L/min | Max50L/min | Max60L/min | Max110L/min | |
Pressure MAX | 1.2BAR | 1.2BAR | 1.2BAR | 1.5BAR | 1.5BAR | |
Refrigerant | R-404A/R507C/R448A | |||||
Dimension cm | 45*70*160 | 45*70*160 | 55*70*175 | 65*85*185 | 70*85*185 | |
Power max | 6.5kW | 8kW | 13kW | 18kW | 26kW | |