CTC760E Instrument Transformer Analyzer

<p>CTC760E Instrument transformer analyzer can carry out a series of standard tests quickly, such as determining the magnetization characteristic, saturation behavior (ALF/FS), transformation ratio and its accuracy, polarity, load, winding resistance, or remanence. Tests are performed in accordance with standards: IEC60044-1, IEC60044-6, IEC 61869, ANSI/IEEE C57.13.1.<br/></p>

SupplierShiJiaZhuang Handy Technology Co.,Ltdwww.handy-china.com

About this product

Product information from the supplier.

FEATURES:

Use direct current method and variable frequency method (low frequency method) testing CT

excitation characteristic below 80KV, working fast.

Use both “voltage method” (through secondary injection) testing current transformer ratio and polarity (include

transformer bushing CTs).

Built-in power supply has an output current mode. Can use current method test current transformer ratio, polarity and check the integrity of the CT secondary circuit.

Output up to 200A with external current booster (option)

Test current transformer secondary winding DC resistance.

Test current transformer secondary circuit burden.

Test voltage transformer excitation characteristic, ratio, polarity and secondary winding DC resistance.

Draw the excitation curve and calculating the knee point accordance to IEC60044-1 and IEC60044-6.

Draw 5%, 10% CT error curve.

Measure CT’s ratio error and phase displacement.

Measure CT’s remanence factor (Kr), magnetizing inductance (Lm), secondary loop time constant (Ts), transient dimensioning factor (Ktd), peak instantaneous error (PIE), accuracy limit factor (ALF), instrument security factor (FS).

Draw current transformer Hysteresis loop curve

Transparent display shows values and curve clearly both indoor and outdoor.

High speed thermal printer can print values and curve.

Check the connecting cable automatically. Wrong connecting warning instructions.

Built-in large memory storage can store 20000 winding test values, loss of power without loss of values.

Use a USB flash drive to transfer the values to PC, and generate report.

Use a USB flash drive to update software.

 

SPECIFICATIONS:

Output Voltage: 0~360V AC

Output Current: 0~10Arms, peak 20A

External Current Booster Output Current: 0~200A AC

External Current Booster Output Current Duration: 8min at 150A

Output Power: 0~3600VA

Secondary Voltage Measurement Range: 2~360V AC

Secondary Voltage Measurement Accuracy: ±(0.1%U+20mV)

Primary Voltage Measurement Range: 0~20V AC

Output Current Measurement Range: 0.01~10A AC

Output Current Measurement Accuracy: ±(0.1%I+2mA)

Secondary Current Measurement Range: 0~5A AC

Secondary Current Measurement Accuracy: ±(0.1%I+2mA)

Winding Resistance Measurement Range: 0~300Ω, resolution 1mΩ

Winding Resistance Measurement Accuracy: ±(0.1%R+1mΩ)

AC Load Measurement: 0~1000VA, resolution 0.001VA

Transformation Ratio Measurement Range: 1~35000

Rated Current Transformation Ratio Error: ±0.1% for 1~5000; ±0.2% above 5000

Rated Current Phase Error: 3min at cosφ=0.8~1, resolution 0.1min

Power Supply: 198~264V AC, 47~63Hz

Operating Conditions: Temperature -10℃~50℃, Humidity ≤90%RH, non-condensing

Main Unit Dimensions: 427×357×193mm

Main Unit Weight: 11kg

Current Booster Dimensions: 327×282×218mm

Current Booster Weight: 12k