Chemicals

High Purity Angiotensin A CAS 34273126 China Suppliers and Factory

Source high-purity Angiotensin A CAS 34273-12-6 from leading China suppliers. Our factory provides research-grade decapeptide precursors essential for ACE activity assays and RAS studies, ensuring 99% purity for pharmaceutical drug discovery and cardiovascular research.

SupplierGlobal Technology Co., Ltd.www.hqtechtirz.com
Source categories

About this product

Product information from the supplier.

Angiotensin A (CAS NO. 34273-12-6) is a premium research-grade decapeptide serving as a critical biologically inactive prohormone. It is the primary substrate for Angiotensin-Converting Enzyme (ACE), undergoing enzymatic cleavage to generate the potent vasoactive peptide Angiotensin II. This essential conversion triggers systemic physiological responses, including vasoconstriction and aldosterone synthesis, making Angiotensin A an indispensable tool for studying the Renin-Angiotensin-Aldosterone System (RAAS).

Engineered for high-precision laboratory applications, our Angiotensin A is produced under strict quality controls to ensure a purity of ≥99.0%. It is specifically indicated for pharmaceutical drug discovery, biochemical assay development, and the calibration of mass spectrometry and HPLC methods. By providing a stable and reliable substrate, it enables researchers to quantify ACE activity and evaluate the efficacy of antihypertensive candidates in high-throughput screening platforms.

Detailed Parameters

Product NameAngiotensin ACAS NO.34273-12-6
AppearanceWhite to off-white lyophilized powderMolecular FormulaC56H78N16O13
Molecular Weight1183.34 g/molPurity (RP-HPLC)≥99.0%
SolubilityWater, dilute acetic acid, or PBS (pH 7.4)Endotoxin≤0.5 EU/mg
Storage ConditionsStore at -20°C, dry and darkStock LocationUSA

Key Advantages

Ultra-High Purity

Guaranteed purity of ≥99.0% via RP-HPLC, ensuring consistent and reproducible results in sensitive biochemical assays.

Rapid Conversion

Optimized as a benchmark substrate for ACE, allowing rapid and complete conversion to Angiotensin II in vitro.

GMP Compliance

Produced by partners utilizing GMP-compliant systems with full batch traceability and standardized QC processes.

RAAS Modeling

Reliably replicates hypertensive states in animal models for testing cardiovascular and renal interventions.

Low Endotoxin

Strictly controlled endotoxin levels (≤0.5 EU/mg), making it ideal for cell-based studies and signal transduction profiles.

Full Documentation

Each batch is accompanied by a COA, HPLC purity report, and MS chromatograms for absolute transparency.

Product Gallery

Management Platforms

Quality Control

Rigorous HPLC and Mass Spectrometry validation for every production batch.

GMP Production

Strict adherence to GMP and FDA standards in our synthesis and purification labs.

Batch Traceability

Complete documentation from raw material procurement to final lyophilization.

Stability Monitoring

Continuous monitoring of storage conditions at -20°C to ensure long-term potency.

Global Logistics

Secure air freight via DHL/FedEx with specialized temperature-controlled packaging.

Technical Support

Professional guidance on solubility and reconstitution for diverse research needs.

Investment Return Comparison

Evaluation MetricStandard GradeGlobalTech High-Purity
Purity Level95% - 98%≥99.0% (Certified)
Batch ConsistencyModerate VariationHigh Stability (COA Provided)
Conversion EfficiencyVariable RatesOptimized Michaelis-Menten Km
Endotoxin LevelUnspecified≤0.5 EU/mg
Research ReliabilityBasic ScreeningPharmaceutical-Grade Validation

Frequently Asked Questions

Q: What is the primary application of Angiotensin A in pharmaceutical research?

It is primarily used as a substrate for ACE activity assays, allowing researchers to evaluate the inhibitory potency of ACE inhibitor drugs and study the RAAS cardiovascular pathways.

Q: How should Angiotensin A be stored to maintain its biological activity?

It must be stored at -20°C in a dry, dark, and well-sealed container. It is critical to avoid repeated freeze-thaw cycles to prevent peptide degradation.

Q: Is this product suitable for clinical use in humans?

No, Angiotensin A is strictly designated for laboratory research, drug discovery, and biochemical assays. It is not a clinical therapeutic agent.

Q: In which solvents is Angiotensin A soluble?

The product is soluble in water, dilute acetic acid, or Phosphate Buffered Saline (PBS) at pH 7.4. It is insoluble in common organic solvents like ethanol or methanol.

Q: What quality certifications accompany each shipment?

Each batch comes with a complete Certificate of Analysis (COA), RP-HPLC purity reports, and Mass Spectrometry (MS) chromatograms to verify identity and purity.

Q: Can Angiotensin A be used for animal model induction?

Yes, it is frequently used in preclinical animal studies to induce experimental hypertension by replicating the overactivation of the RAAS system.

Request a Quote for High-Purity Angiotensin A Today

Contact Us